Most serious switchgear incidents occur during isolation, racking, testing or the return to service. This programme focuses on those steps for low and medium voltage switchgear and motor control centres: identifying all energy sources, withdrawable and fixed breaker isolation, interlocks and earthing switches, lockout/tagout, live-dead-live testing, test positions and temporary removal of isolations, and controlled de-isolation and re-energisation. Practical exercises use typical switchgear arrangements found in Gulf oil, gas, utilities and building services.

الحصول على الكتيب

للحصول على كتيب بكامل محتويات الدورة برجاء ملء النموذج التالي ببياناتك الصحيحة

تحميل الكتيب

دورات مشابهة
الهندسة الكهربائية
الهندسة الكهربائية
الهندسة الكهربائية
مارس
، 2027
الإنجليزية
دبي
$3,600.00
الهندسة الكهربائية
يونيو
، 2027
الإنجليزية
أبو ظبي
$3,600.00
NEVADA | PROFESSIONAL EXPERIENCE

Program Professional Framework

Electrical Isolation and De-Isolation Requirements for Electrical Switchgears

Program Overview

Most serious switchgear incidents occur during isolation, racking, testing or the return to service. This programme focuses on those steps for low and medium voltage switchgear and motor control centres: identifying all energy sources, withdrawable and fixed breaker isolation, interlocks and earthing switches, lockout/tagout, live-dead-live testing, test positions and temporary removal of isolations, and controlled de-isolation and re-energisation. Practical exercises use typical switchgear arrangements found in Gulf oil, gas, utilities and building services.

Learning Outcomes

  • ✓Identify every source of supply, back-feed and stored energy for a switchgear panel using drawings.
  • ✓Plan an isolation sequence including racking out, locking, earthing and tagging of the correct devices.
  • ✓Perform live-dead-live verification with a proven voltage tester and record the result.
  • ✓Manage temporary de-isolation for testing while keeping the work party protected.
  • ✓Execute a controlled de-isolation and re-energisation sequence with pre-energisation checks and handover.

Target Audience

  • Electrical technicians and isolating authorities
  • Electrical maintenance supervisors
  • Permit issuers and area authorities
  • Commissioning engineers handling switchgear energisation

Detailed Program Modules

01Switchgear Types and Energy Sources
  • LV and MV switchgear and MCC arrangements
  • Withdrawable and fixed circuit breakers
  • Back-feeds, control supplies and stored energy
02Isolation Planning
  • Reading single-line and schematic drawings
  • Selecting isolation points and verifying identity
  • Isolation records and interface with permits
03Locking, Tagging and Interlocks
  • Personal and group lockout
  • Mechanical and key interlocks
  • Earthing switches and their limitations
04Verification of Isolation
  • Live-dead-live testing method
  • Selecting and proving test instruments
  • Discharging capacitive and stored energy
05Testing and Temporary De-Isolation
  • Test and service positions
  • Sanction for test controls
  • Re-applying isolation after testing
06De-Isolation and Return to Service
  • Pre-energisation inspection and insulation tests
  • Removal of locks, earths and tags
  • Energisation sequence and handover

Training Methodology

Interactive expert-led sessions grounded in workplace examples
Case studies and practical exercises drawn from the region
Group workshops with peer review of decisions and deliverables
Formative feedback against clear performance criteria

Applied Project & Assessment

Applied Project

Participants prepare an isolation and de-isolation plan for maintenance on an MV feeder panel and its connected MCC, covering energy source identification, isolation points, lock and tag register, verification records and the return-to-service checklist.

Assessment

Short diagnostic at the start, practical tasks linked to each learning outcome, and evaluation of the applied project against published criteria.